R-22 Wall Mounted Type (Heat Pump) |
Introduction
Upgrade to an even more quit and compact system (thinner and lighter).
Models :
Cooling Only
FH-21/26/30/36/42/48,
Heat Pump
FHY-35/50/60/71/100/125
Comfort |
Cooling Only |
Heat Pump |
Auto Swing
Delivers comfortable air-conditioning to all areas, near
to and far from the air-conditioner. |
 |
 |
Draft Prevention Function |
 |
 |
Switchable fan speed
High setting provides maximum reach while low setting
minimizes drafts |
 |
 |
Program ‘Dry’
Dehumidification is computer controlled to prevent abrupt
and uncomfortable changes in air temperature. Useful for
reducing discomforting humidity without uncomfortable
cooling of the room. |
 |
 |
High ceiling application
Delivers air-conditioning comfort all the way down to
the floor in air-conditioning zones with high ceilings. |
 |
 |
Two selectable thermo-sensors
Thermo-sensors are included in the indoor unit and optional
wired remote controller. Termperature detection closer
to target area is possible to further increase the fomfort
level. *Use the thermo-sensor in the indoor unit
when controlling air conditioning from another room. |
 |
 |
Hot Start
Uncomfortable cold air draft is avoided when heating operation
starts or when switching to transparent, the drain heat
after defrosting. |
 |
 |
Year-round cooling applicable
Efficient cooling even in winter when indoor temperatures
are higher than those outside, such as in undergroung
public spaces or office with many computers.
* Heat pump/RY71 - 140LU: possible up to -50C
*Cooling only/RY71 - 140LU: possible up to -150C
(An option is required.) |
 |
 |
Time Selector
Operation starts when the preset time of the ON timer
elapses and stops when the preset time of the OFF timer
elapses. |
 |
 |
Control Features |
Cooling Only |
Heat Pump |
Auto-restart If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored. |
 |
 |
Auto Cooling/heating Change-over |
 |
 |
Interlock control Enables interlocking control with external equipment such as heat reclaim ventilation (HRV). |
 |
 |
Control by 2 remote
Using 2 remote controllers you can operate the equipment
locally or from a remote location. Note: When
a wireless remote controller is used, remote control by
two remote controllers is not possible. |
 |
 |
Control by 1 remote controller
You can turn up to 16 indoor units on/off with a single
remote controller. (When using connected indoor units,
the settings must all be the same and on/off will be simultaneous.) |
 |
 |
External command control
Operation and surveillance is carried out using the contact
signal from the operation control box in teh building
surveillance (security) room. |
 |
 |
Central remote control
Optional central remote controller enables centralized
control of up to 1024 indoor units (64 groups) from up
to 1 Kilometer away. |
 |
 |
Work & Servicing |
Cooling Only |
Heat Pump |
Drain Pump mechanism If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging. |
 |
 |
Pre-charged for up to 15 m If refrigerant piping length does not exceed 15 m, there is no need for on-site gas charging. |
 |
 |
Pre-charged for up to 30 m If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging. |
 |
 |
Filter sign The filter sign warns you when it is time to clearn the filter. * When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the singnal receiver unhit. |
 |
 |
Low gas pressure detection Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by computer to ensure proper gas pressure. Reliability is assured and maintenance and inspection can be carried out more quickly. |
 |
 |
Emergency operation
If there is a malfunction elsewhere in the system, the fan or compressor can still be operated. |
 |
 |
Self-diagnosis function
The operating parameters of indoor and outdoor units, and sensosr data at critical locations throughout the system, are constantly monitored using a microcomputer. To facilitate quick response in the event of a malfunction, a message appears on the LCD of the remote controller and an LED on the unit illuminates. |
 |
 |
Mould prevention |
Cooling Only |
Heat Pump |
Mold resistant treatment for filter Sanitary filter has mold-resistant treatment. |
 |
 |
Mould-proofing drain plan Mildew proofing maintains hygiene by preventing growth in highly humid conditions. |
 |
 |
Option |
Cooling Only |
Heat Pump |
Life long filter
Even in smoky environments where the air conditioner is
on most of the time, the ultra long-life filter only has
to be changed once a year. |
 |
 |
Others |
Cooling Only |
Heat Pump |
Twin/triple/double twin multi operation
Simultaneously operates 2-4 indoor units with a single outdoor unit. |
 |
 |
PE fin
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heatt exchanger of the outdoor unit. |
 |
 |
 |
Installable
on max. 3.5 m high ceiling |
 |
Applicable when wired
remote controller is used |
 |
Applicable to R71LU-R140LU
outdoor units (for temp. down to - 15°C) (An option
is required.) |
 |
Applicable to RY71LU-RY140LU
outdoor units (for temp. down to-5°C) and RY200LU-RY250LU
outdoor units (for temp. down to-0°C) |
 |
Optional available |
 |
Applicable to R(Y)71LU-140LU
outdoor units. |
|
* Power Supply ( 1/3 Phase) |
|